Ditch-witch MV800 User Manual Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 111
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
Prepare - 34 MV800 Operator’s Manual
Prepare Jobsite
CMW
®
Prepare Jobsite
Prepare Excavation Point
Clear the area to be excavated. Remove rocks or branches too large for vacuum hose.
If excavating fluids while drill string is moving, clear area of trees, shrubs, and weeds.
Select a solid area to stand on while excavating.
Jobsite hazards could cause death or serious injury. Use
correct equipment and work methods. Use and maintain proper safety
equipment.
274-050
To help avoid injury:
Classify jobsite as electric if jobsite classification is in question or if the possibility of unmarked
electric utilities exists.
Expose lines by hand before digging.Cutting high voltage cable can cause electrocution.
All vegetation near operators station must be removed. Contact with trees, shrubs, or weeds during
electrical strike could result in electrocution.